Clinical automatic chemical analyzer Clinical chemical reagent chemical analysis

Advanced Hospital Bench Top Automatic Chemistry Analyzer (YJ-300)Product DescriptionHigh End Full Automatic biochemistry analyzerSpecification:  Throughput constant 300T/h,  Closed integrated photovoltaic systems, no mechanical parts,maintenance free  Minimum reaction volume is 150ul,cost saving&nbs

Featured Products


Advanced Hospital Bench Top Automatic Chemistry Analyzer (YJ-300)
Clinical Automatic Chemistry Analyzer Clinical Chemistry Reagents Chemistry Analyze


Product Description
High End Full Automatic biochemistry analyzer
Specification:
  Throughput constant 300T/h,
  Closed integrated photovoltaic systems, no mechanical parts,maintenance free
  Minimum reaction volume is 150ul,cost saving
  Discrete,random access,automatic
  Random choice of method, the real discrete automatic chemistry analyzer
  This automatic chemistry analyzers have gained a lot of national patents during the researching.
  Clinical Automatic Chemistry Analyzer Clinical Chemistry Reagents Chemistry Analyze
Analyze Unit
l  Throughput: constant 300 T/h, 81 reaction cuvette positions,multi-channel testing together.
l  Minimum reaction volume is 150μl, cost saving.
l  Determined by the sample sequence, inserted at any time emergency.
l  Heating method: Direct thermal solid thermostat closed.

Optical Unit
l  Closed integrated photovoltaic systems, no mechanical parts,maintenance free.
l  Light Source:Halogen-tungsten lamp;
l  Lifetime≥2000 h.
l  8 Wavelength,support single or dual wavelength.


Reagent Unit
l  80 reagent positions.
l  Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
l  15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
l  Support for single and double reagent, reagent completely open.
Internal barcode reader (option).

Sample Unit
l  80 sample positions.
l  Testing according setting,random access.
l  Real time display of testing status.
l  Internal barcode reader (option).

Reagent/Sample handing Unit
l  Intelligent liquid detection & collision protection (Red light: collision; Blue light: detection of the liquid).
l  Reagent volume: 2 ~ 100μl,step by 1μl .
l  Probe cleaning:automatically washing for both inside and outside,carry over0.1%.
l  Automatically dilute and retest.

Calibration and quality control Unit
l  Linear curve type:Single-point linear,two-point linear and multi-point linear.
l  Nonlinear curve type:Logit-4p,Logit-5p,polynomial,factor.
l  Automatically use best calibration curve and standard.
l  Quality control chart:L-J,Westgard TwinPlot,Cumulative.

Operation Unit 
l  Operation system: Windows XP/Office 2000,interface is intuitive and operate it easily, arbitrary operating authority;No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
l  Can print the contents of any custom;Offers a variety of print formats.
l  Help and operation guide on line in English.
l  No restrictions on setting test parameters.
l  Unique password for user management,rational allocation of user rights.
l  Real time display of testing status,the remaining amount of reagent,testing status ,reaction curve and the test progress.
l  Real time display of reaction plate temperature.
RS-232 standard interface,support for the hospital network, print reports remotely.
 
Others
l  Temperature:15-30 degree
l  Humidity:35-85%.
l  Try to avoid strong light.
l  Floor level up:less than 1/200.
l  Barometric:86.0kPa-106.0kPa.
l  Power Supply:AC 220V-240V 50/60Hz±1 Hz. 1000W or 100V-200V 60HZ 1000W
l  Water consumption:less than 18L/h.
l  Frequency:550 VA.
l  Dimension:912mm×721mm×570mm
l  Weight:60kg
 
Test projects

l  ALT,AST,TP,ALB,TBIL,DBIL,ALP,r-GT,CHE,TBA,5-NT
l  UREA,CR,UA,TCO2
l  CHOL,TG,HDL,LDL,ApoA,ApoB,LPa
l  AMY,LIP
l  GLU,GSP
l  CK,CK-MB,a-HBDH,LDH,MB
l  CRP,RF,ASO

 
YJ-300
Automatic Chemistry Analyzer
Specifications
Analyze Unit
ThroughputConstant 3000T/h (non-ISE)
TheoryAbsorption spectrometry, transmission turbidimetry
MethodologyEnd-point \Fixed-time\Kinetic\Ion selective electrode
Test according set up, random access
Reaction plateContain 120 reaction cuvettes
Maximum reaction time15 minutes
Minimum reaction volume150 ul
Material of cuvettesSpecial UV-transparent optical glass
Cuvettes useAutomatically cuvettes washing
Optical Unit
Light SourceHalogen-tungsten lamp
PhotometerReversed optics
Wavelength340nm-670nm wavelength option
Absorption0-4.0 Abs(10mn conversion)
Reagent Unit
Reagent plate80 reagent positions ,support for single and double reagent, reagent completely open
Reagent storage temperature4~10 degree
Reagent bottle15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml
Reagent volumeR1:150-300 ul,R2:20-150ul  step by 1.0 ul
Reagent/Sample ProbeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Sample Unit
Sample plate120 sample positions
Sample typeHuman (animal) serum \plasma\urine etc.
Samples cupSupport one-off micro cups
Sample volume2-100 ul, step by 0.1 ul
Sample/reagent probeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Temperature control Unit
Heating methodDirect thermal solid thermostat closed
Temperature equilibrium time<3 minutes
Reaction temperature37 ±0.1 degree
Temperature fluctuation±0.1 degree
 
Operation Unit
SoftwareWindowsXP \2000
DatabaseSQL Server
Data StorageAutomatic store & copy; No time and volume limit; Lifetime preservation
Print formatCan be set up, offer several standard format
Calibration modeLinear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard
Quality control methods :Real time, within day & between day
Quality control diagramL-J \cumulative\twin plot
Status displayReal time monitoring of reagent residual volume .Running status of reagent tray, samples tray
AdjustmentDynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages         
SettingOperation permission setting, Item setting, cross pollution setting, cuvette blank setting
Others
Water consumption : < 18L/hPower Supply :AC 220V-240V 50/60Hz 1000W or 100V-200V 60HZ 1000W
Frequency :Maximum 600VADimension :912mm×721mm×570mm
Net Weight : 60kgAccessory :Software
 
   

Note:We provides you with12-24 months free repair guarantee for main unit, 12 months free repair guarantee for probe and 6 months free repair guarantee for the optional parts respectively.More information for our products and service,please turn to our official website or contact us directly.



Relative Products:
Clinical Automatic Chemistry Analyzer Clinical Chemistry Reagents Chemistry Analyze




 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours